Server
Characteristics
| Name | Unit | Default value | Description | Example |
|---|---|---|---|---|
| usage | None | See server usage | .. | |
| cpu | None | See cpu | .. | |
| ram | None | See ram | .. | |
| disk | None | See ssd & hdd | SSD or HDD | .. |
| motherboard | None | See motherboard | .. | |
| power_supply | None | See power_supply | .. | |
| assembly | None | See assembly | Assembly phase | .. |
| case | None | See case | Enclosure | .. |
Server usage
In addition to the characteristics available for usage, you can use the following:
| Name | Unit | Default value (default;min;max) | Description | Example |
|---|---|---|---|---|
| other_consumption_ratio | None | 0.33;0.2;0.6 | Power consumption ratio of other components (except disks) relative to RAM and CPU | 0.2 |
| gpu_time_workload | % | 65;0;100 | Load of the server's GPUs, as a percentage between 0 and 100 | 80 |
Complete
The following components are completed with the characteristics taken from the archetype :
Embedded impacts
Impacts criteria
| Criteria | Implemented | Source |
|---|---|---|
| gwp | yes | Bottom-up approach based on Green Cloud Computing, 2021 |
| adp | yes | Bottom-up approach based on Green Cloud Computing, 2021 |
| pe | yes | Bottom-up approach based on Green Cloud Computing, 2021 |
| gwppb | yes | Base IMPACTS® ADEME |
| gwppf | yes | Base IMPACTS® ADEME |
| gwpplu | yes | Base IMPACTS® ADEME |
| ir | yes | Base IMPACTS® ADEME |
| lu | yes | Base IMPACTS® ADEME |
| odp | yes | Base IMPACTS® ADEME |
| pm | yes | Base IMPACTS® ADEME |
| pocp | yes | Base IMPACTS® ADEME |
| wu | yes | Base IMPACTS® ADEME |
| mips | yes | Base IMPACTS® ADEME |
| adpe | yes | Base IMPACTS® ADEME |
| adpf | yes | Base IMPACTS® ADEME |
| ap | yes | Base IMPACTS® ADEME |
| ctue | yes | Base IMPACTS® ADEME |
| ctuh_c | yes | Base IMPACTS® ADEME |
| ctuh_nc | yes | Base IMPACTS® ADEME |
| epf | yes | Base IMPACTS® ADEME |
| epm | yes | Base IMPACTS® ADEME |
| ept | yes | Base IMPACTS® ADEME |
Bottom-up approach
Fix impact factors
| Criteria | Unit | value |
|---|---|---|
| ir | kg U235 eq. | 2320.0 |
| lu | No dimension | -147.0 |
| odp | kg CFC-11 eq. | 0.00135 |
| pm | Disease occurrence | 0.000113 |
| pocp | kg NMVOC eq. | 8.4 |
| wu | m3 eq. | -3710.0 |
| mips | kg | 10600.0 |
| adpe | kg SB eq. | 0.0378 |
| adpf | MJ | 51500.0 |
| ap | mol H+ eq. | 19.7 |
| ctue | CTUe | 48400.0 |
| ctuh-c | CTUh | 1.94e-07 |
| ctuh-nc | CTUh | 1.87e-05 |
| epf | kg P eq. | -0.258 |
| epm | kg N eq. | 2.94 |
| ept | mol N eq. | 27.0 |
Usage impact
Both power consumption and consumption profile are implemented.
Consumption profile
A server consumption profile is of the form :
\(\text{CP}_{\text{CPU}}(\text{workload})\) and \(\text{CP}_{\text{RAM}}(\text{workload})\) depend on the technical
characteristics of the RAM and CPU.
\(\text{P}_{\text{disks}}\) is the power of the local drives: a constant power per drive (see SSD
and HDD) multiplied by the number of drives. It is added outside of
\(\text{other_consumption_ratio}\), so that the drives are not counted twice.
\(\text{P}_{\text{GPU}}\) is the power of one GPU: its avg_power if given, otherwise modelled from its TDP
(see GPU). It is also added outside of \(\text{other_consumption_ratio}\).
\(\text{gpu_workload}\) is gpu_time_workload, 65% by default: it does not follow the server's time_workload. A time_workload set in the GPU's own usage takes precedence.
\(\text{other_consumption_ratio}\) is used to account for the electrical consumption of the other components (other than RAM,
CPU and disks).