Skip to content

Server

Characteristics

Name Unit Default value Description Example
usage None See server usage ..
cpu None See cpu ..
ram None See ram ..
disk None See ssd & hdd SSD or HDD ..
motherboard None See motherboard ..
power_supply None See power_supply ..
assembly None See assembly Assembly phase ..
case None See case Enclosure ..

Server usage

In addition to the characteristics available for usage, you can use the following:

Name Unit Default value (default;min;max) Description Example
other_consumption_ratio None 0.33;0.2;0.6 Power consumption ratio of other components relative to RAM and CPU 0.2

Complete

The following components are completed with the characteristics taken from the archetype :

Embedded impacts

Impacts criteria

Criteria Implemented Source
gwp yes Bottom-up approach based on Green Cloud Computing, 2021
adp yes Bottom-up approach based on Green Cloud Computing, 2021
pe yes Bottom-up approach based on Green Cloud Computing, 2021
gwppb yes Base IMPACTS® ADEME
gwppf yes Base IMPACTS® ADEME
gwpplu yes Base IMPACTS® ADEME
ir yes Base IMPACTS® ADEME
lu yes Base IMPACTS® ADEME
odp yes Base IMPACTS® ADEME
pm yes Base IMPACTS® ADEME
pocp yes Base IMPACTS® ADEME
wu yes Base IMPACTS® ADEME
mips yes Base IMPACTS® ADEME
adpe yes Base IMPACTS® ADEME
adpf yes Base IMPACTS® ADEME
ap yes Base IMPACTS® ADEME
ctue yes Base IMPACTS® ADEME
ctuh_c yes Base IMPACTS® ADEME
ctuh_nc yes Base IMPACTS® ADEME
epf yes Base IMPACTS® ADEME
epm yes Base IMPACTS® ADEME
ept yes Base IMPACTS® ADEME

Bottom-up approach

\[ \begin{equation} \begin{aligned} \text{server}_\text{embedded}^\text{criteria} & = \sum_{\set{\text{components}}}{\text{component}_ \text{embedded}^\text{criteria}} \\ \\ & = \text{cpu_units} * \text{CPU}_{embedded}^{criteria} \\ & \quad + \ \text{ram_units} * \text{RAM}_{embedded}^{criteria} \\ & \quad + \ \text{ssd_units} * \text{SSD}_{embedded}^{criteria} \\ & \quad + \ \text{hdd_units} * \text{HDD}_{embedded}^{criteria} \\ & \quad + \ \text{motherboard}_{embedded}^{criteria} \\ & \quad + \ \text{power_supply_units} * \text{power_supply}_{embedded}^{criteria} \\ & \quad + \ \text{assembly}_{embedded}^{criteria} \\ & \quad + \ \text{enclosure}_{embedded}^{criteria} \end{aligned} \end{equation} \]

Fix impact factors

Criteria Unit value
ir kg U235 eq. 2320.0
lu No dimension -147.0
odp kg CFC-11 eq. 0.00135
pm Disease occurrence 0.000113
pocp kg NMVOC eq. 8.4
wu m3 eq. -3710.0
mips kg 10600.0
adpe kg SB eq. 0.0378
adpf MJ 51500.0
ap mol H+ eq. 19.7
ctue CTUe 48400.0
ctuh-c CTUh 1.94e-07
ctuh-nc CTUh 1.87e-05
epf kg P eq. -0.258
epm kg N eq. 2.94
ept mol N eq. 27.0

Usage impact

Both power consumption and consumption profile are implemented.

Consumption profile

A server consumption profile is of the form :

\[ \text{CP}_{\text{component}} = \text{consumption_profile}_{\text{component}} \]
\[ \text{CP}(\text{workload}) = (\text{CP}_{\text{CPU}}(\text{workload}) + \text{CP}_{\text{RAM}}(\text{workload})) * (1 + \text{other_consumption_ratio}) \]

\(\text{CP}_{\text{CPU}}(\text{workload})\) and \(\text{CP}_{\text{RAM}}(\text{workload})\) depend on the technical characteristics of the RAM and CPU. \(\text{other_consumption_ratio}\) is used to account for the electrical consumption of the other components (other than RAM and CPU).